           Clean Streams Ozone Systems For Cooling Towers


 

 

 


Saves Water and Money, Eliminates Chemicals and Improves the
Treatment and Safety of Cooling Water Systems

 Description: Clean Streams™ Ozone Systems for Cooling Towers provide a stand-alone, continuous and automated treatment for cooling water systems. Ozone keeps heat transfer surfaces free of biofilm and allows higher system cycling without chemicals, resulting in significant water savings. Scale and deposits are controlled by preventing biofilm development on surfaces, thereby preventing scale to form or deposits to accumulate. Corrosion is controlled by cycling the water¡¯s mineral content up to a level that is outside the corrosion range.

Ozone is a powerful biocide that kills all microorganisms through oxidation, destroying them and leaving no chance for developing an immunity that often occurs with chemical biocides. Ozone treated cooling systems are noted for the clarity and low bacteria counts of the recirculating water. In a typical ozone treated system, bacteria counts are less than 100 per ml, and often non detectable. The superior disinfection power of ozone prevents biofilm growth and provides protection against pathogenic organisms like Legionella pneumophilia, the causative agent of Legionnaire¡¯s disease that is often traced to contaminated cooling water systems.

Benefits of Clean Streams™:

    •       Eliminates Chemicals - No spills, no drums to handle or dispose.
    •       Automated System with Full Service - Provides full time treatment and simplifies operation.
    •       Lowers Operating Cost - Lower water cost and more efficient heat transfer.
    •       Makes Workplace Safer - No chemical exposure.
    •       Blowdown Contains No Hazardous Chemicals - Can avoid discharge to sewer and makes alternative
            uses, such as irrigation, possible.
    •       Saves Water - Operate system at higher cycles of concentration.
    •       Reduces Tower Maintenance - Fewer cleanouts required

Typical Water Savings: On a tower of 500-ton capacity, water savings of over 3 million gallons per year can be realized, based upon operation of the tower at 10 cycles of concentration with ozone versus 3 on chemical treatment.
This equates to a savings of $15,300 per year on water alone, and a payback on the ozone system of 19 months. Larger systems have quicker paybacks ¨C a 1000-ton tower can have a payback in about one year.
Leasing the system can also be an attractive option and in most cases produce positive cash flow savings from the first day of operation.
 

cleanstreams1.jpg

Drawing of Skid Mounted Unit
cleanstreams2.jpg

Drawing of Wall Mounted Unit cleanstreams3.jpg

 Specifications:

MODEL

Tons

Dimensions

Electrical

Notes

CS-200W

200

4 x 3 feet

220V, 30A,  1 Phase  

 Wall mounted

CS-400W  

400

4 4 feet

 220V, 40A,  1 Phase 

Wall mounted

CS-400S  

400

  4tx 2x 5.3 feet

220V, 40A,  1 Phase    

Skid mounted

CS-600S  

600

4x 2x 5.3 feet

220V, 30A, 1+N

Skid mounted

CS-850S

850

4x 2 x 5.3 feet

220V, 30A, 3+N

Skid mounted

CS-1200S

1200

Call Sales

220V, 30A, 3+N

Skid mounted

CS-1700S

1700

Call Sales

 220V, 50A, 3+N

Skid mounted

CS-2800S

2800

Call Sales

20V, 70A, 3+N

Skid mounted

 
         

 

 