Saves
Water and Money, Eliminates Chemicals
and Improves the Treatment and Safety of Cooling Water Systems
Description:
Clean Streams™ Ozone Systems for Cooling Towers provide a stand-alone,
continuous and automated treatment for cooling water systems. Ozone
keeps heat transfer surfaces free of biofilm and allows higher system
cycling without chemicals, resulting in significant water savings.
Scale and deposits are controlled by preventing biofilm development
on surfaces, thereby preventing scale to form or deposits to accumulate.
Corrosion is controlled by cycling the water¡¯s mineral content
up to a level that is outside the corrosion range.
Ozone
is a powerful biocide that kills all microorganisms through oxidation,
destroying them and leaving no chance for developing an immunity
that often occurs with chemical biocides. Ozone treated cooling
systems are noted for the clarity and low bacteria counts of the
recirculating water. In a typical ozone treated system, bacteria
counts are less than 100 per ml, and often non detectable. The superior
disinfection power of ozone prevents biofilm growth and provides
protection against pathogenic organisms like Legionella pneumophilia,
the causative agent of Legionnaire¡¯s disease that is often traced
to contaminated cooling water systems.
Benefits
of Clean Streams™:
• Eliminates
Chemicals - No spills, no drums to handle or dispose. • Automated
System with Full Service - Provides full time treatment and
simplifies operation. • Lowers
Operating Cost - Lower water cost and more efficient heat transfer. • Makes
Workplace Safer - No chemical exposure. • Blowdown
Contains No Hazardous Chemicals - Can avoid discharge to sewer
and makes alternative uses,
such as irrigation, possible. • Saves
Water - Operate system at higher cycles of concentration. • Reduces
Tower Maintenance - Fewer cleanouts required
|
|
Typical
Water Savings: On a tower
of 500-ton capacity, water savings of over 3 million gallons per
year can be realized, based upon operation of the tower at 10 cycles
of concentration with ozone versus 3 on chemical treatment. This
equates to a savings of $15,300 per year on water alone, and a payback
on the ozone system of 19 months. Larger systems have quicker paybacks
¨C a 1000-ton tower can have a payback in about one year. Leasing
the system can also be an attractive option and in most cases produce
positive cash flow savings from the first day of operation.
|

|
|
Drawing
of Skid Mounted Unit

|
Drawing
of Wall Mounted Unit 
|
|
Specifications:
|
|
MODEL
|
Tons
|
Dimensions
|
Electrical
|
Notes
|
|
CS-200W
|
200
|
4
x 3 feet
|
220V,
30A, 1 Phase
|
Wall
mounted
|
|
CS-400W
|
400
|
4
4 feet
|
220V,
40A, 1 Phase
|
Wall
mounted
|
|
CS-400S
|
400
|
4tx
2x 5.3 feet
|
220V,
40A, 1 Phase
|
Skid
mounted
|
|
CS-600S
|
600
|
4x
2x 5.3 feet
|
220V,
30A, 1+N
|
Skid
mounted
|
|
CS-850S
|
850
|
4x
2 x 5.3 feet
|
220V,
30A, 3+N
|
Skid
mounted
|
|
CS-1200S
|
1200
|
Call
Sales
|
220V,
30A, 3+N
|
Skid
mounted
|
|
CS-1700S
|
1700
|
Call
Sales
|
220V,
50A, 3+N
|
Skid
mounted
|
|
CS-2800S
|
2800
|
Call
Sales
|
20V,
70A, 3+N
|
Skid
mounted
|
|
|
|
|
|
|