4KVA Solid State
Frequency Converter Specifications
|
|||||
|
Model |
4KSS60400/50400 | ||||
|
Capacity |
4KVA/3.2KW | ||||
|
Input | |||||
|
Voltage |
120V or 220V *see note | ||||
|
Voltage Range |
-15%/+20% | ||||
|
Current |
220V - 20.9A @ Full Load (31.4A @ Current limit) | ||||
|
120V - 38.3A @ Full Load (57.5A @ Current limit) | |||||
|
Frequency |
50Hz or 60Hz ±5% | ||||
|
Phase |
Single | ||||
|
Output | |||||
|
Voltage |
120V (Locked) | ||||
|
Voltage Regulation |
±1% | ||||
|
Frequency |
400Hz | ||||
|
Frequency Regulation |
±0.016Hz (Xtal oscillator) | ||||
|
Harmonic Distortion |
<3% (100% linear load.) | ||||
|
Output Waveform |
Pure Sinewave | ||||
|
Output Current @ .8pf |
220V - 18.1A | ||||
|
120V - 33.3A | |||||
|
Overload@150% for 30 seconds |
220V - 27.2A | ||||
|
120V - 50A | |||||
|
Efficiency |
| ||||
|
AC to AC |
>85% | ||||
|
|
| ||||
|
Power Factor |
0.8 | ||||
|
Crest Factor |
3:1 | ||||
|
Indicator- Detachable& Remote Control | |||||
|
LCD |
Automatically configures to monitor voltage, frequency and loading, simultaneously. | ||||
|
LED |
| ||||
|
Audible Alarm | |||||
|
Overload |
Continuously beeping | ||||
|
Fault |
Continuously beeping | ||||
|
Protection | |||||
|
Overload |
150% delay 30 seconds, current limited | ||||
|
Short Circuit |
Current limited cut-off, fuse and breaker | ||||
|
EMI filter |
10-100KHz at 40dB; 100KHz-100MHz at 70dB | ||||
|
Over Temperature |
Inverter auto cut-off when heatsink temp. over 80ºC | ||||
|
Dimension | |||||
|
Depth |
22.9in/58cm | ||||
|
Width |
9.63in/24.5cm | ||||
|
Height |
27.75in/70.5cm | ||||
|
Environment | |||||
|
Operation Temperature |
-10 to 50° C; 14-122° F | ||||
|
Relative Humidity |
20-90% (non-condensing) | ||||
|
Noise Level |
< 58dB (at 1 meter) | ||||
|
Weight | |||||
|
LBS/KG |
232lbs/105.5kg (on wheels) | ||||
|
Note: Input voltages of 208V single phase (phase-to-phase on a 3-phase 120/208V line)- with 2 hot lines and 240V single phase (from a 120/20V split-phase source) - 2 hot lines are both acceptable with one hot on the input N ternimal, and another hot on the L2 input terminal. | |||||
1Specifications subject to change without notice.